NEW IX-EN-4062 | Technical Information NEW IX-EN-4062 Latest X-ray inspection technology for entry level users makes for an easy investment choice Using the latest in X-ray technology, this system is the most affordable choice for ensuring product quality. This model is most purposeful in handling light, thin products, possessing the required sensitivity to accurately detect faults and contaminants. Dimensions in mm 700 705 430 540 870 865 1960 1745 325 900 ±50 720 800 Specifications Tunnel aperture Construction Width Height Material IP Rate Machine dimensions Machine weight Dimensions Conveyor Belt height Speed Loaded weight Product length Minimum spacing between products Power supply Tube voltage X-ray Tube current Output Line sensor X-ray protection X-ray emissions Working environment Temperature Humidity IX-EN-4062 400mm 150mm SUS304 (Polished surface – Bead blast option) Conveyor chamber: IP66 / Enclosure: IP54 (IP65, option) 800mm(L)x870mm(W)x1745mm(H) (*1) (Floor to Signal Tower: 1960mm) 290kg 800mm(L) x 430mm(W) (1800mm optional (L)) 900mm +/- 50mm (*2) 10-60m/min 5kg (higher weight is optional) 20~450mm (optional 1000mm) (*3) 30mm (*3) Single phase: AC200-240V 50/60Hz 450W (*4) 30/35/40/45/50/55kV 1mA Max: 55W 0.6mm Protective curtains (*5) Machine meets local regulations 0-33°C (*6) 30-85%RH Belt Surface 215 400 Inspection area The figures show the permissible inspection range. Portions of the product which are not within the shaded area are not irradiated. 150 Product Size (mm) Height (*7) Width 0 400 10 387 20 375 30 363 40 350 50 338 60 326 70 314 80 301 90 289 100 277 110 264 120 256 130 240 140 228 150 215 Design and specifications are subject to change without notice. (*1) This dimension shall be applied in case of 900mm belt height. (*2) Other heights optional. (*3) This dimension should be followed under Snap-Mode only. In case of Bulk-Mode, not applied. (*4) 450W is applied in case of no specific ancillary. (*5) The material of protection curtain is tungsten, and curtain is detachable. (*6) If the room is hotter than 33°C, the air conditioner shall be arranged as a chargeable option. In this case, the maximum temperature is 40°C. (*7) The inspection width against the height is approximate value. All information supplied within is correct at time of publication. Ishida Europe pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Ishida Europe shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material.
Download PDF file
Cookie policy