NEW IX-EN-2463 | Technical Information NEW IX-EN-2463 Latest X-ray inspection technology for entry level users makes for an easy investment choice Using the latest in X-ray technology, this system is the most affordable choice for ensuring product quality. This model is most purposeful in handling light, thin products, possessing the required sensitivity to accurately detect faults and contaminants. Dimensions in mm 700 705 270 710 120 245 460 705 1960 1745 900 ±50 720 800 Specifications Tunnel aperture Construction Width Height Material IP Rate Machine dimensions Machine weight Dimensions Conveyor Belt height Speed Loaded weight Product length Minimum spacing between products Power supply Tube voltage X-ray Tube current Output Line sensor X-ray protection X-ray emissions Working environment Temperature Humidity IX-EN-2463 240mm 120mm SUS304 (Polished surface – Bead blast option) Conveyor chamber: IP66 / Enclosure: IP54 (IP65, option) 800mm(L)x710mm(W)x1745mm(H) (*1) (Floor to Signal Tower: 1960mm) 250kg 800mm(L) x 270mm(W) (1800mm optional (L)) 900mm +/- 50mm (*2) 10-60m/min (optional 90m/min) 5kg (higher weight is optional) 20~450mm (optional 1000mm) (*3) 30mm (*3) Single phase: AC200-240V 50/60Hz 500W (*4) 30/35/40/45/50kV 1mA Max: 50W 0.4mm Protective curtains (*5) Machine meets local regulations 0-33°C (*6) 30-85%RH Belt Surface 169 240 Inspection area The figures show the permissible inspection range. Portions of the product which are not within the shaded area are not irradiated. Product Size (mm) Height (*7) Width 0 240 10 234 20 228 30 222 40 216 50 210 60 204 70 198 80 192 90 186 100 180 110 175 120 169 Design and specifications are subject to change without notice. (*1) This dimension shall be applied in case of 900mm belt height. (*2) Other heights optional. (*3) This dimension should be followed under Snap-Mode only. In case of Bulk-Mode, not applied. (*4) 500W is applied in case of no specific ancillary. (*5) The material of protection curtain is tungsten, and curtain is detachable. (*6) If the room is hotter than 33°C, the air conditioner shall be arranged as a chargeable option. In this case, the maximum temperature is 40°C. (*7) The inspection width against the height is approximate value. All information supplied within is correct at time of publication. Ishida Europe pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Ishida Europe shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material.
Download PDF file
Cookie policy